CV Thermostat Error Codes
CV Temperature Control/ Thermometer Set Up Sheet 10/10/07sb Correct Settings CAL = -5° / TC = H / HYS = 5° Calibration Offset (CAL) – The correct setting...
Contact US | About Us | Cart | My Account | Schedule Service | Apply for financing. Learn more
17 lenders are ready to fight for your business
How much money would you lose if your smoker went down?
Call Today To Schedule Your Maintenance or Repair
CV Temperature Control/ Thermometer Set Up Sheet 10/10/07sb Correct Settings CAL = -5° / TC = H / HYS = 5° Calibration Offset (CAL) – The correct setting...
When replacing the black door handle w/ chrome ends on an old style K series smoker the new door handles use screws size 1/4-20. You may have to drill out...
Cook & Hold thermostat displaying an error message? Find out more by reading this service bulletin. Service Bulletin SP2018-001.0
When it comes to your Southern Pride smoker, understanding the meaning behind the burner ignition control module light codes is crucial for proper maintenance and troubleshooting. Each light code indicates...
If you have a vibrating convection motor just replacing the fan blade may not resolve your issue completely. Check the shaft of the motor where it feeds through the wall...
If your convection fan motor is shaking badly you either have a dirty fan blade, faulty rubber bushing, or bad motor bearings. If the shaft of the motor is moving...
If your GFCI or breaker box breaker are tripping when you open up the meat doors of your smoker you likely are having an issue with either the interior light...
Most parts for the BBR-79-SE have been discontinued, but you're in luck replacing the convection motor if your BBR-79 came with a Fastco convection motor. You can retrofit a...
SPK-500 with a K serial # never had an interlock switch above the door. Only on side panel.
If you're Southern Pride smoker with a mechanical thermostat is working fine except the rotisserie will not work except by using a foot pedal you likely have a faulty NC (Normally...
Some very old smokers came equipped with a high limit that used a capillary tube which is no longer available. This can be replaced with bi-metal high limit assembly found...
Attached images show the setup of the old style smoke extractor damper linkage system arms.
Error Code Err IN is the CV thermostat controller not finding the thermocouple. It is a bad thermocouple connection or the thermocouple wires are on the wrong terminals. Thermocouple wires...